118 research outputs found

    Devices for SRF material characterization

    Get PDF
    The surface resistance R s of superconducting materials can be obtained by measuring the quality factor of an elliptical cavity excited in a transverse magnetic mode (TM010). The value obtained has however to be taken as averaged over the whole surface. A more convenient way to obtain R s, especially of materials which are not yet technologically ready for cavity production, is to measure small samples instead. These can be easily manufactured at low cost, duplicated and placed in film deposition and surface analytical tools. A commonly used design for a device to measure R s consists of a cylindrical cavity excited in a transverse electric (TE110) mode with the sample under test serving as one replaceable endplate. Such a cavity has two drawbacks. For reasonably small samples the resonant frequency will be larger than frequencies of interest concerning SRF application and it requires a reference sample of known R s. In this article we review several devices which have been designed to overcome these limitations, reaching sub-nΩ resolution in some cases. Some of these devices also comprise a parameter space in frequency and temperature which is inaccessible to standard cavity tests, making them ideal tools to test theoretical surface resistance models

    COPPER PROTOTYPE MEASUREMENTS OF THE HOM, LOM AND SOM COUPLERS FOR THE ILC CRAB CAVITY

    Get PDF
    Abstract The ILC Crab Cavity is positioned close to the IP and delivered luminosity is very sensitive to the wakefields induced in it by the beam. A set of couplers were designed to couple to and damp the spurious modes of the crab cavity. As the crab cavity operates using a dipole mode, it has different damping requirements from an accelerating cavity. A separate coupler is required for the monopole modes below the operating frequency of 3.9 GHz (known as the LOMs), the opposite polarization of the operating mode (the SOM), and the modes above the operating frequency (the HOMs). Prototypes of each of these couplers have been manufactured out of copper and measured attached to an aluminum nine cell prototype of the cavity and their external Q factors were measured. The results were found to agree well with numerical simulations

    Bunch length measurements using a transverse deflecting cavity on VELA

    Get PDF
    The VELA facility at Daresbury Laboratory in the UK includes a 5 MeV/c 2.5 cell S-band photoinjector gun. This gun operates in the "blow-out" regime with a sub-200 fs length drive laser: the resulting bunch length is determined by space-charge effects. We present measurements made with an S-band transverse deflecting cavity to characterise the bunch length as a function of charge, and as a function of the gun operating phase

    Crab cavities for linear colliders

    Full text link
    Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.Comment: 3 pages. To be published in proceedings of LINAC 2008, Victoria, Canad

    Low secondary electron yield of laser treated surfaces of copper, aluminium and stainless steel

    Get PDF
    Reduction of SEY was achieved by surface engineering through laser ablation with a laser operating at • = 355 nm. It was shown that the SEY can be reduced to near or below 1 on copper, aluminium and 316LN stainless steel. The laser treated surfaces show an increased surface resistance, with a wide variation in resistance found de-pending on the exact treatment details. However, a treated copper surface with similar surface resistance to aluminium was produced

    The conceptual design of CLARA, a novel fel test facility for ultra-short pulse generation

    Get PDF
    CLARA will be a novel FEL test facility focussed on the generation of ultra-short photon pulses with extreme levels of stability and synchronisation. The principal aim is to experimentally demonstrate that sub-cooperation length pulse generation with FELs is viable, and to compare the various schemes being championed. The results will translate directly to existing and future X-ray FELs, enabling them to generate attosecond pulses, thereby extending their science capabilities. This paper gives an overview of the motivation for CLARA, describes the facility design (reported in detail in the recently published Conceptual Design Report [1]) and proposed operating modes and summarises the proposed areas of FEL research
    • …